SPECIFICATION OF GI EARTHING ELECTODE
Model No | Pipe Dia (mm)) | Length (M) | Terminal Size |
SO-GIPS481 | 48 | 1 | 40X6 |
SO-GIPS482 | 48 | 2 | 40X6 |
SO-GIPS483 | 48 | 3 | 40X6 |
SO-GIPS761 | 76 | 1 | 50X6 |
SO-GIPS762 | 76 | 2 | 50X6 |
SO-GIPS763 | 76 | 3 | 50X6 |
We are the leading manufacturer and supplier of all types of chemical earthing elecrodes
Chemical earthing are widely used in electrical earthing application this earthing electrode has long life and low conductivity as compare to conventional earthing. This earthing are maintenance free which doesn't required any watering they have low resistance ohmic value which is maintained for long duration normally without any changes for years.
GI Earthing Electrode:- Gi earthing electrodes are galvanised earthing electrode which has zinc coating that helps prevent corrosion this electrodes are most economical.
our electrodes are manufactured with high grade and superior quality of material. this electrodes have GI strip inside pipe which is connected to end terminal at top of electrode the strip helps in fast discharge of fault current. GI chemical earthing electrodes are filled with conductive compund between pipe and strips this conductive compound is a good conductor of electricity which also helps to discharge the fault current easily to ground.
Using strip and compound reduces overall resistance of the electrode no of earthing electrodes can be reduced by using chemical earthing as the resistance value of chemical earthing is always lesser than conventional earthing
Availaible in
GI Earthing Electrode:-GI strip in pipe earthing electrode / Gi pipe in pipe earthing electrode
Feutures.
Maintenance free no need for pouring water
Less space required for installtion.
Less exposer to corrosion due to zinc coating.
Having good conductivity.
CPRI tested.
Quick Installation.
Can be customized as per requirement.
Long Life upto 8 years.
Application.
Residential and comercial building for electrical equipments and meter room.
Diesel Generator Set for body and Neutral.
Lightning Arrester.
Electrical Substation.
factories,warehouses
Down load chemical earthing electrode drawing
Products.
Chemical earthing electrode
GI Earthing Electrode
GI Strip in Pipe Earthing Electrode
GI Pipe in Pipe Earthing Electrode
Copper Earthing Electrode
Copper Bonded Pipe in strip Earthing Electrode
Copper Bonded Pipe in Pipe Earthing Electrode
Lightning Arrester
Conventional lightning Arrester
Early Steamer
Lightning Arrester Accessories
Back Fill compound
Earthing Pit Cover
PVC Chamber
CI Chamber
MS Chamber
Earthing Connector